Leak Detection Installation
Leak-detection sensing cable, spot detectors and controllers for data centers, installed and calibrated in BC and Alberta.
The problem
What's at stake
Liquid cooling puts water where it was never allowed before: inside the rack row. Insurance and warranty questions after an event always start with the same line: show us your detection. Detection that was never installed, or installed but never calibrated and tested, is the most common gap we see.
LDI-03 · SCOPE
- Detection design mapped to your actual loop: CDU perimeter, manifold runs, rack rows, drip trays, risers
- Sensing cable and spot detectors from established, serviceable North American brands
- Controller configuration, BMS/DCIM integration and alarm routing
- Full calibration with documented test of every zone
- As-built documentation: zone map, device schedule, test log
What you receive
A commissioned detection system with an as-built package: zone map, calibration certificates, alarm test records and integration notes. Everything a future auditor, insurer or new facilities manager will ask for.
Our commitment
We install brands with a real service future, never orphaned hardware. Every zone is physically wet-tested before we call the job done, and you watch the alarm arrive.
FAQ
Common questions
How much does leak detection installation cost for a data center?
Each installation is quoted individually, because the cost depends on how many zones need coverage and how your loop is laid out. A room with one CDU and a short manifold run is a very different job from multiple rack rows with risers and drip trays. Send the basics through the contact form on this site and you will get a quote scoped to your facility, covering cable runs, spot detectors, controller work and testing.
What happens during a leak detection installation?
The work runs in four stages: design, install, integrate, and test. First the detection layout is mapped to your actual loop, covering the CDU perimeter, manifold runs, rack rows, drip trays and risers. Then sensing cable and spot detectors go in, the controller is configured, and alarms are routed into your BMS or DCIM. Finally every zone is calibrated and physically wet-tested, and you leave with a zone map, device schedule and test log.
Can leak detection be installed around live racks without downtime?
In most cases, yes, leak detection can be installed around live racks without IT downtime. Sensing cable and spot detectors are low-voltage devices that typically go in around operating equipment without touching the IT load, and installation can be planned zone by zone around your maintenance windows. Wet testing places a small, controlled amount of water directly on the sensor, not on your hardware. Anything that needs a coordinated window, such as tying alarms into your BMS or DCIM, can be identified and scheduled before work starts.
How do I know the leak detection system actually works after installation?
Every zone is physically wet-tested before the job is called done, and you watch the alarm arrive yourself. The handover package includes calibration certificates, alarm test records, a zone map, a device schedule and integration notes, which is the documentation an insurer or auditor asks for after an event. Detection that was installed but never calibrated and tested is the most common gap in liquid-cooled sites, so the test log matters as much as the hardware.